Japanese | English | Sitemap
HOME > Product > Static eliminator > Explosion proof

Product Informatoin



Clean space construction Dust removal Static elimination Monitoring and control Medical-related or others
SpaceBarSpecial barGunDesktopAdjust hoseSpotWireless ground

Explosion proof

Specific application

Approved Explosion-proof TRINC

APPROVED EXPLOSION-PROOF Features Applications
GUN TRINC
TAS-23 GL-EPA
•Explosion proof
•Powerful static elimination
•High reliability and easy maintenance
•Painting, Printing
•Chemical factory
•Powder production
A new approved explosion-proof gun-type ionizer "GUN TRINC" for anti-static/dust measures in dangerously flammable atmosphere.
APPROVED EXPLOSION-PROOF GUN TRINC
TAS-23 GL-EPA
Much safer with further intensified explosion-protection performance.
A new approved explosion-proof ionizer for anti-static/dust measures in the dangerously flammable atmosphere
Features Applications
  • ■Explosion-proof
  • ■Super wide area ionizing
  • ■Super low power consumption
  • ■One-touch cleaner
  • ■Painting / Printing
  • ■Tire manufacturing
  • ■Petrochemical plant
  • ■Fine particle manufacturing
  • ■Rubber manufacturing
  • ■Car body repairing
TRINC's discharge needle has a long life. TRINC products have an easy maintenance such as one-touch cleaning and auto-cleaning, but sometimes users tend to forget to clean the needle. When the ionizer has been used for long time, discharge needle has come worn out and effectiveness of static elimination may reduce. The periodical exchange of needle is recommended.



The more flammable a location is, the more likely static is built up.
Safety static elimination in such ambience as filled with flammable gases has now become possible. TRINC has developed a new approved explosion-proof ionizer ”GUN TRINC” with a further improved explosion-protection performance as compared with the conventional.

Feature 1

Prevention of explosion by static
Under the material processing environment filled with solvent vapor and scattering particles, the spark caused by static would lead directly to an explosion or fire. So the antistatic measures are indispensable for safety and efficient operation. The TRINC Approved Explosion-proof type ionizer, which has been proved in the various production sites, promises the explosion or fire-free environment as well as safe and high efficiency operation.

Feature 2

Prevention of quality from being damaged by static and dusts
The dusts sticking to work piece largely affect the paint surface finishing quality. However, what is really needed for the painting in the environment including flammable solvents is the anti-static/dust measures with assured explosion-proof. The Approved Explosion-proof TRINC dissipates the static charged on products with powerful ions to prevent the dust-related defects.

Feature 3

Power saving (except an air source)
Extremely low power consumption has been realized.
APPROVED EXPLOSION-PROOF GUN TRINC: 5.5W


APPROVED EXPLOSION-PROOF Features Applications
BAR TRINC
TAS-36 BAM-EPA
•Explosion proof
•Powerful static elimination
•High reliability and easy maintenance
•Painting, Printing
•Chemical factory
•Powder production
A new approved explosion-proof ionizer "BAR TRINC" for anti-static/dust measures in the dangerously flammable atmosphere.
APPROVED EXPLOSION-PROOF BAR TRINC
TAS-36 BAM-EPA
Much safer with further intensified explosion-protection performance.
A new approved explosion-proof ionizer for anti-static/dust measures in the dangerously flammable atmosphere.
Features Applications
    • ■Explosion-proof
    • ■Super wide area ionizing
    • ■Super low power consumption
    • ■One-touch cleaner
  • ■Painting / Printing
  • ■Tire manufacturing
  • ■Petrochemical plant
  • ■Fine particle manufacturing
  • ■Rubber manufacturing
  • ■Car body repairing
TRINC's discharge needle has a long life. TRINC products have an easy maintenance such as one-touch cleaning and auto-cleaning, but sometimes users tend to forget to clean the needle. When the ionizer has been used for long time, discharge needle has come worn out and effectiveness of static elimination may reduce. The periodical exchange of needle is recommended.



The more flammable a location is, the more likely static is built up.
Once an explosion or a fire occurs, all the measures taken go back to square one. TRINC has developed a new approved explosion-proof ionizer with a further improved explosion-protection performance as compared with the conventional.

Feature 1

Prevention of explosion by static
Under the material processing environment filled with solvent vapor and scattering particles, the spark caused by static would lead directly to an explosion or fire. So the antistatic measures are indispensable for safety and efficient operation. The Approved Explosion-proof TRINC, which has been proved in the various production sites, promises the explosion or fire-free environment as well as safe and high efficiency operation.

Feature 2

Prevention of quality from being damaged by static and dusts
The dusts sticking to work piece largely affect the paint surface finishing quality. However, what is really needed for the painting in the environment including flammable solvents is the anti-static/dust measures with assured explosion-proof. The Approved Explosion-proof TRINC dissipates the static charged on products with powerful ions to prevent the dust-related defects.

Feature 3

One-touch cleaner function
Most static ionizers installed inside equipment have faced a problem that they reduce gradually ion-discharging. This is because they are located out of reach for daily maintenance and the dust piled up on needles prevents ions from being discharged. As a result, static elimination becomes ineffective and product defect rate grows higher. Putting itself in customer’s shoes, TRINC has developed a static ionizer with a manual cleaning system. With a one-touch to turn the grip mounted on the edge of the ion-bar, a dozen of needles are cleaned in a lump. This is a patent TRINC is granted first in the field.

Feature 4

Various sizes available
The ion-bars are available in 3 sizes; 500, 1,000 and 1,500mm. This enables customers to choose the ion-bar to match their purposes for ionizing in a wide space to that in a narrow inside of the equipment.

Feature 5

Discharge needle cleaning notification function
If the discharge needle becomes dirty, the static electricity removal capacity will decrease and it will not be possible to sufficiently remove static electricity. The Explosion-Proof BAR TRINC detects the dirt on the discharge needle and turns on the cleaning LED of the discharge needle. By performing maintenance (cleaning, needle replacement, etc.) of the discharge needle, it can always be used in good condition without causing a decrease in static elimination capacity.

Feature 6

Overhaul notification function
The overhaul LED lights up when 4 years have passed in the actual working time (cumulative). By overhauling, it will return to the original state.
     * Overhaul will be done by TRINC.


APPROVED EXPLOSION PROOF Features Applications
PHASE ARRAY IONIZER
TAS-83 SFS-EPA
•Explosion-proof
•Ultra-wide static elimination
•High reliability and easy maintenance
•Painting, Printing
•Chemical
•Powder
A new approved explosion-proof PHASED ARRAY IONIZER for anti-static/dust measures in dangerously flammable atmosphere.
APPROVED EXPLOSION-PROOF PHASED ARRAY IONIZER
TAS-83 SFS-EPA
Much safer with further intensified explosion-protection performance.
A new approved explosion-proof ionizer for anti-static/dust measures in the dangerously flammable atmosphere
Features Applications
  • ■Explosion-proof
  • ■Super wide area ionizing
  • ■Super low power consumption
  • ■One-touch cleaner
  • ■Painting / Printing
  • ■Tire manufacturing
  • ■Petrochemical plant
  • ■Fine particle manufacturing
  • ■Rubber manufacturing
  • ■Car body repairing
TRINC's discharge needle has a long life. TRINC products have an easy maintenance such as one-touch cleaning and auto-cleaning, but sometimes users tend to forget to clean the needle. When the ionizer has been used for long time, discharge needle has come worn out and effectiveness of static elimination may reduce. The periodical exchange of needle is recommended.



The more flammable a location is, the more likely static is built up.
Once an explosion or a fire occurs, all the measures taken go back to square one. TRINC has developed a new approved explosion-proof ionizer with a further improved explosion-protection performance as compared with the conventional.

Feature 1

Prevention of explosion by static
Under the material processing environment filled with solvent vapor and scattering particles, the spark caused by static would lead directly to an explosion or fire. So the antistatic measures are indispensable for safety and efficient operation. The TRINC Approved Explosion-proof type ionizer, which has been proved in the various production sites, promises the explosion or fire-free environment as well as safe and high efficiency operation.

Feature 2

>Prevention of quality from being damaged by static and dusts
The dusts sticking to work piece largely affect the paint surface finishing quality. However, what is really needed for the painting in the environment including flammable solvents is the anti-static/dust measures with assured explosion-proof. The Approved Explosion-proof phased array ionizer to prevent the defect from being caused by the dust adhesion.

Feature 3

One-touch cleaner function
Most static ionizers installed inside equipment have faced a problem that they reduce gradually ion-discharging. This is because they are located out of reach for daily maintenance and the dust piled up on needles prevents ions from being discharged. As a result, static elimination becomes ineffective and product defect rate grows higher. Putting itself in customer’s shoes, TRINC has developed a static ionizer with a manual cleaning system. With a one-touch to turn the grip mounted on the edge of the ion-bar, a dozen of needles are cleaned in a lump. This is a patent TRINC is granted first in the field.

Feature 4

Various sizes available
The ion-bars are available in 3 sizes; 500, 1,000 and 1,500mm. This enables customers to choose the ion-bar to match their purposes for ionizing in a wide space to that in a narrow inside of the equipment.

Feature 5

Discharge needle cleaning notification function
If the discharge needle becomes dirty, the static electricity removal capacity will decrease and it will not be possible to sufficiently remove static electricity. The Explosion-Proof BAR TRINC detects the dirt on the discharge needle and turns on the cleaning LED of the discharge needle. By performing maintenance (cleaning, needle replacement, etc.) of the discharge needle, it can always be used in good condition without causing a decrease in static elimination capacity.

Feature 6

Overhaul notification function
The overhaul LED lights up when 4 years have passed in the actual working time (cumulative). By overhauling, it will return to the original state.
     * Overhaul will be done by TRINC.


総合お問合せ窓口

Phased Array Ionizing”, “No-Blow Ionizing”, “Ion Engine”, “Slight-Air Ionizing” are registered trademark (in Japan) of TRINC Corporation, a forerunner of this field.

Announcement
• Recruiting
• Demo Center Network
• New Product Information
• Event Information
• Media Information
• Promotion Videos
• Applications

 
Link
• TRINC Consulting
• TRINC Library
• TRINC METHOD
• Static Electricity / Dust Book
• Static Electricity Museum
• Story of Static Electricity

 
Contact us
• General Inquiry Counter
• Inquiry about product
• Price Inquiry
• Inquiries about distributors
• Online demonstration and disucussion
• Demo Center Visit Reseravation
• Anything Consultation


Support
• Products User Registration
• After-Sales Service

Related Brand
• LOHEN

SNS
• Facebook
• YouTube